SNF Calculation formula for milk used in various states
SNF Calculation formula for milk used in various states
SNF Calculation formula for milk used in various states
Sl. No.
|
State
|
Formula
|
Remarks
|
1
|
Gujarat
|
CLR/4 + 0.21(Fat%) + 0.36
|
Lactometer calibrated at 21 deg C
|
2
|
West Bengal
|
CLR/4 + 0.21(Fat%) + 0.36
|
Lactometer calibrated at 15.5 deg C
|
3
|
Orissa
|
CLR/4 + 0.21(Fat%) + 0.36
|
Lactometer calibrated at 15.5 deg C
|
4
|
WAMUL, Assam
|
CLR/4 + 0.20(Fat%) + 0.66
|
Lactometer calibrated at 29 deg C
|
5
|
Maharashtra
|
CLR/4 + 0.21(Fat%) + 0.36
|
Lactometer calibrated at 21 deg C
|
6
|
Goa
|
CLR/4 + 0.21(Fat%) + 0.36
|
Lactometer calibrated at 21 deg C
|
7
|
MP
|
CLR/4 + 0.20(Fat%) + 0.70
|
Lactometer calibrated at 29 deg C
|
8
|
UP
|
CLR/4 + 0.20(Fat%) + 0.29
|
Lactometer calibrated at 15.5 deg C
At DCS level it is CLR/4+0.20(Fat%) + 0.5 (Lactometer at 29 deg C)
|
9
|
Punjab
|
CLR/4 + 0.20(Fat%) + 0.29
|
Lactometer calibrated at 15.5 deg C
|
10
|
Haryana
|
CLR/4 + 0.20(Fat%) + 0.29
|
Lactometer calibrated at 15.5 deg C
|
11
|
BIS
|
CLR/4 + 0.25(Fat%) + 0.44
|
Lactometer calibrated at 27 deg C
|
12
|
Tamil Nadu
|
CLR/4 + 0.20(Fat%) + 0.36
|
Lactometer calibrated at 21 deg C
|
13
|
Karnataka
|
CLR/4 + 0.25(Fat%) + 0.35
|
Lactometer calibrated at 27 deg C
|
14
|
A P
|
CLR/4+.21(Fat%)+.36
|
Lactometer calibrated at 21 deg C
|
15
|
Kerala
|
CLR/4 + 0.20(Fat%) + 0.50
|
Lactometer calibrated at 29 deg C
|
16
|
Pataliputra(Bih)
|
CLR/4 + 0.20(Fat%) + 0.14
|
Lactometer calibrated at 15.5 deg C
|
17
|
Rest of Bihar
|
CLR/4 + 0.20(Fat%) + 0.66
|
Lactometer calibrated at 29 deg C
|
from Prajjawal Traders
osa chauraha manjhanpur Kaushambi
Why divide
ReplyDeleteCLR BY 4 ?
https://play.google.com/store/apps/details?id=com.milkvolume.milkvolumecalculation
Deleteअलग अलग राज्य के लिये अलग अलग snf फॉर्म्युला क्यो ? Plz explain it.
ReplyDeletehttps://play.google.com/store/apps/details?id=com.milkvolume.milkvolumecalculation
DeletePlease send me contact no 8708180414
DeleteMILK QUALITY IS DIFFERENT FROM ANY DIFFERENT STATE'S ACCORDING TO ENVIRONMENT.
DeleteMay I ask,
ReplyDelete1. Why CLR is divided by 4 and fat% by 5 in the formula number 16?
2.why 0.14 has added in the same formula? What is it called and how it comes?
Clr stands for what?
ReplyDeletecorrect lactometer reading
DeleteHow to correct lactometer reading at different temperatures
ReplyDeleteYes difrence
DeleteAdd 0.2 for each degree celcius of temp after 20'c
Deletewhy banglore having high temparature than AP
ReplyDeleteWhy clr divided by 4 and why fat multiplied with.21 and y last .36 added in ap is there any reason plz give reply
ReplyDeleteMilk SNF and Total solids calculation app
ReplyDeletehttps://play.google.com/store/apps/details?id=com.milkvolume.milkvolumecalculation
What is 0.21
ReplyDeleteAre you aware about the milk analyzer? Prompt's ultrasonic milk analyzer measures and records milk fat, SNF, added water and milk density. The milk testing equipment ensures transparency and optimum earnings to farmer and dairy.
ReplyDeleteI am from Punjab,. How to calculate fat and snf rates, ,,,,,,,,,,,,, i mean powder rate in milk
ReplyDelete1:8
DeleteWhy is the factor used in this formula? What is the purpose of adding both the factors
ReplyDeleteWhat is 0.36
ReplyDeleteContact Prompt Equipment for the smart and indigenous milk analyzer which is Bluetooth enabled and provides secured calibration.
ReplyDeleteWhat is the formula for j&k
ReplyDeleteI appreciate you sharing such a great blog. Let NK Dairy Equipment, one of the leading dairy equipment manufacturers, know if you require assistance managing your farm or dairy store. Their equipment is of the highest calibre.
ReplyDeleteGreat and that i have a swell offer you: What To Expect When Renovating A House old house renovation ideas
ReplyDelete